MeiTrack VT310 User Manual Page 15

  • Download
  • Add to my manuals
  • Print
  • Page
    / 21
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 14
- 15 -
=0,cancle
=[1,4294967295] meter(s)
Distance interval is suggested to be set above 300 meters.
Example:
40 40 00 14 40 20 50 20 81 4F FF 43 03 33 30 30 9B C5 0D 0A
Above command will set interval as 300 meters.
Response:
$$<L><ID><0x4303><Flag><checksum> \r\n
Note:
Flag
=0x00, failure response;
=0x01, success response.
24. Delete Mileage 0x4351
Command:
@@<L><ID><0x4351><checksum> \r\n
Description:
Delete total mileage of GPRS packets.
When mileage is deleted, the server should have a corresponding program to avoid
calculation mistake.
Note:
If mileage is accelerated to 4294967295 meters, it will be deleted automatically.
Example:
40 40 00 11 40 10 47 20 21 3F FF 43 51 40 48 0D 0A
Response:
$$<L><ID><0x4351><Flag><checksum> \r\n
Note:
Flag
=0x00, failure response;
=0x01, success response.
25. Reboot GPS 0x4902
Command:
@@<L><ID><0x4902> <checksum>\r\n
Description:
Reboot the GPS module of the tracker.
Example:
40 40 00 11 12 34 56 FF FF FF FF 49 02 71 AC 0D 0A
Response:
$$<L><ID><0x4902><Flag><checksum> \r\n
Note:
Flag
=0x00, failure response;
=0x01, success response.
26. Heartbeat 0x5199
Command:
@@<L><ID><0x5199><data><checksum> \r\n
Description:
Set time interval for heartbeat mode.
Note:
data=[0,65535], in ASCII code and in unit of minute
Example:
40 40 00 13 12 34 56 FF FF FF FF 51 99 31 32 24 89 0D 0A
Above command will set interval as 12 minutes. The tracker will send heartbeat (0x00)
data to the server every 12 minutes.